SenTec

Air compressor pressure switch

Air compressor pressure switch is mainly used to adjust the start and stop status of the air compressor. By adjusting the pressure in the air tank, the air pressure switch can be stopped and rested, which has a protective effect on the machine.

Air compressor pressure switch diagram

A compressors always has two pressure set-points: the cut-in and the cut-out set point.

These are simply the two pressures at which the compressor starts and stops. The compressor will stop when it reaches the cut-out pressure by air compressor high pressure switch point and will start again when the pressure drops back to the cut-in pressure by air compressor low pressure switch point. 

The graph below shows a typical air compressor pressure switch diagram. The horizontal axis shows the cut-out pressure and the vertical axis the cut-in pressure. The shaded area shows the range in which the switch can operate. 

How does a air compressor pressure switch work ?

After the air compressor is debugged in the factory, the air compressor tank pressure switch can be adjusted to the specified pressure according to the customer’s needs, and then set the differential pressure. For example, when the compressor starts to start, pump air into the air storage tank, when the pressure reaches 7bar(125PIS), the air compressor stops or relieves pressure; when the pressure drops to 5bar(75PSI), the air compressor starts again. There is a pressure difference between them. During this process, the compressor can be stopped to protect the air compressor.

When deciding what the best pressure is for you and your compressor, always remember to set the pressure as low as possible for your application.

Most air compressor set with air compressor pressure switch 120-150 psi(8-10Bar). But if you only need 5 or 6 bar, it’s better to lower the pressure.

How to adjust air compressor pressure switch ?

Different air compressor shut off switch have different adjustment methods.

One is that the pressure difference is fixed by the switch itself, and only the maximum pressure of the automatic shutdown pressure is adjusted. This kind of switch has two knobs for debugging with a flat-blade screwdriver. The two knobs must be adjusted in the same way, otherwise it will stop when it starts, and start again when it stops, which will burn out the electrical appliance.

The other is a regulation starting pressure (low pressure), a regulation stop pressure (high pressure). In this case, just need to set the air compressor switch value.

Air compressor pressure adjustment steps:

a. Rotate the pressure adjustment screw clockwise to increase the closing and opening pressures simultaneously.

b. Rotate the pressure adjustment screw counterclockwise, and the closing and opening pressures decrease simultaneously.

Air compressor differential pressure adjustment steps:

a. Rotate the differential pressure adjustment screw clockwise, the closing pressure remains unchanged, and the opening pressure increases.

b. Rotate the differential pressure adjustment screw counterclockwise, the closing pressure remains unchanged, and the opening pressure decreases.

Air compressor pressure adjustment
Air compressor pressure adjustment

how to wire pressure switch on air compressor ?

The pressure switch wiring diagram air compressor can be simply connected to both ends of the normally closed (NC). When the pressure to unload pressure type disconnect. The air compressor stops running. Closes when the pressure is less than the loading pressure. The air compressor is ready to operate.

Whatever your rigid air compressor pressure switch, square d air compressor pressure switch or other types, Please must pay attention to the power supply may be different, like 220v air compressor pressure switch and 240 Volt air compressor pressure switch. Wrong power supply for the sensor may cause the failures.

Pressure switch wiring diagram air compressor
Pressure switch wiring diagram air compressor
Air compressor pressure switch assembly diagram
Air compressor pressure switch assembly diagram

Reminder

1. The pressure switch of the air compressor must be adjusted by professionals according to the wiring diagram for pressure switch on air compressor guidelines, and the general user cannot adjust it arbitrarily.

2. The air compressor has a rated operating pressure, which refers to the pressure when it is disconnected. For example, if the operating pressure of a general air compressor is 8kg/cm³, the maximum pressure when it is disconnected cannot exceed 8kg/cm³.

to avoid danger.

We have made a basic overview of different models and types of pressure switches. Check out pressure switch product page for more details if you’re interested or if you want to buy a pressure switch.

Share:

Facebook
Twitter
LinkedIn
VK
Tumblr
Email
Print

Table of Contents

Free custom

We support free customized according to your application.