SenTec

sentec

SEM228T Thermoelectric total solar radiation sensor

SEM228T total solar radiation transmitter adopts the thermoelectric principle and can be used to measure solar radiation with a spectral range of 0.3~3μm. The sensing element adopts a wire-wound electroplating thermopile, and the sensing surface is a black layer with high absorptivity. Using the thermal effect of radiation,Absorb solar radiation and convert it into thermoelectromotive force.

SEM228T total solar radiation transmitter adopts the thermoelectric principle and can be used to measure solar radiation with a spectral range of 0.3~3μm. The sensing element adopts a wire-wound electroplating thermopile, and the sensing surface is a black layer with high absorptivity. Using the thermal effect of radiation,Absorb solar radiation and convert it into thermoelectromotive force. It also has a temperature compensation function, which can accurately measure solar radiation. The double-layer glass cover above the sensing surface can not only reduce the influence of air convection on the device, but also block the radiation of the cover itself. And add a radiation shield to measure scattered radiation.

SEM228T support standard analog signal or Modbus-RTU 485 communication protocol, which can directly read the current total solar radiation value, and the wiring method is simple. The appearance is beautiful, and the installation space is small. Products are widely used in solar energy utilization, meteorology, agriculture, building materials aging and air pollution and other departments to measure solar radiation energy.

Parameters

Power supply10V~30V DC, or without power supply
Power consumption485 output: 0.8W

4~20mA/0~5V/0~10V: 1.2W

Output signal485 (standard Modbus-RTU protocol)

4~20mA current output

0~5V/0~10V voltage output

Working temperature-40℃~60℃
Working humidity0%~RH
Sensitivity7~14 μV·W-1·m2
Internal resistanceabout 300Ω
Response time (99%)≤30s
Non-linear error≤±3%
Corresponding error of directionality≤±30W/m² (≤±20W/m² customized)
Temperature response error≤±8% (-40℃~+40℃)
Corresponding error of tilt≤±5%
Spectral range0.3~3μm
Measuring range0-2000W/m²
Resolution1W/m²
Accuracy±3%
Annual stability≤±3%
Spectral selectivity≤±10%
Cosine response error≤±5%

Documents

Take the next step

Get a Quote

Request a quote from us based on your specific requirements

To be a Distributor

If you want to distribute sentec brand in your local area, you can contact us for more.

Installation & Maintain

A group of  professional engineer is here to help your sensor installation & maintenance.