SenTec

sentec

SEM240U Air temperature and humidity sensor

SEM240U air sensor adopts imported digital temperature and humidity sensor, which has been finely calibrated during production, and the calibration data is stored in the internal memory. The sensor has the characteristics of digital output, which can be completely interchanged, does not need to go through a complicated verification and calibration process, and is outstanding in measurement accuracy, linearity, repeatability, interchangeability, and consistency.

SEM240U air sensor adopts imported digital temperature and humidity sensor, which has been finely calibrated during production, and the calibration data is stored in the internal memory. The sensor has the characteristics of digital output, which can be completely interchanged, does not need to go through a complicated verification and calibration process, and is outstanding in measurement accuracy, linearity, repeatability, interchangeability, and consistency.

Using non-dispersive infrared (NDIR) principle, electrochemical sensor and high-performance microprocessor, built-in temperature sensor for temperature compensation, can measure atmospheric temperature and humidity, PM1.0/2.5/10, CO2, oxygen concentration, sulfur dioxide concentration, hydrogen sulfide Concentration, ammonia concentration and formaldehyde, etc.

Parameters

Parameters

Range

Repeatability

Stability

Accuracy

Response time

Air temperature

-30℃~+70℃(Default)

±0.1°C

≤0.04°C/Year

±0.2°C(25°C)

<1S

Air humidity

0~100%RH

±0.1% RH

<0.5%RH/Year

±3%RH(10~90%)

<1S

PM2.5/PM10/PM1.0

0~1000ug/m3

≤1%F.S

≤2%F.S

±3% F.S (25°C)

<90S

CO2

0~5000ppm

≤1%F.S

≤2%F.S

±3% F.S (25°C)

<90S

O2

0~25%Vol

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<15S

SO2

0~20ppm

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<15S

H2S

0~100ppm

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<15S

NH3

0~50ppm

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<15S

CH2O

0~5000ppb

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<60S

Noise

30~130dB

≤1%F.S

≤2%F.S

±2% F.S (25°C)

<15S

Power supply

DC 10-30V(default)

Signal output

RS485, 0~2V, 0~2.5V, 0~10V, 4~20mA

Test parameters

Temperature, humidity, PM, CO2,O2, SO2, H2S, NH3,CH2O, NOISE

Work environment

Temperature – 30 ℃ – 50 ℃; humidity 0 ~ 95% RH, non condensing

Product material

ABS

Installation method

Screw fixed

Documents

Take the next step

Get a Quote

Request a quote from us based on your specific requirements

To be a Distributor

If you want to distribute sentec brand in your local area, you can contact us for more.

Installation & Maintain