SenTec

sentec

SEM321 Wall mounted Carbon monoxide transmitter

SEM321 Wall mounted Carbon monoxide transmitter Using electrochemical technology to measure CO concentration, the reaction is rapid and sensitive. The transmitter is widely used in air quality testing, smart home and other occasions where CO and temperature and humidity testing is required.

SEM321 Wall mounted Carbon monoxide transmitter Using electrochemical technology to measure CO concentration, the reaction is rapid and sensitive. The transmitter is widely used in air quality testing, smart home and other occasions where CO and temperature and humidity testing is required.

Parameters

Power supply

10~30VDC (0~10V type only supply 24VDC)

Average power consumption

0.18W

Accuracy

Temperature

±0.5℃

Humidity

±3%RH

CO

±10%FS

CO Resolution

RS485: 0.1ppm

Analog output: 0.5ppm

CO range

RS485: 0~2000ppm(default)

Analog output: 0~1000ppm (default)

Temperature&humidity range

-40~+80℃  0~100%

Working temperature

-20℃~+50℃

Working humidity

15%RH~90%RH

Data update time

2s

Stability

<10%

Response time

90% step change is generally less than 50S

Output signal

RS485、4~20mA、0~5V、0~10V

Documents

Take the next step

Get a Quote

Request a quote from us based on your specific requirements

To be a Distributor

If you want to distribute sentec brand in your local area, you can contact us for more.

Installation & Maintain