SenTec

sentec

SI100 Series Voltage/current Isolator

SI100 voltage/current isolator isolates and transmits DC voltage or current signals, converting them into the required signals for other instruments. It can be used in conjunction with unit combination instruments, DCS, PLC and other systems to provide on-site instrument signal isolation, signal conversion, signal distribution, signal processing and other functions, thereby improving the anti-interference ability of the industrial production process automatic control system and ensuring the stability and reliability of the system.

SI100 voltage/current isolator isolates and transmits DC voltage or current signals, converting them into the required signals for other instruments. It can be used in conjunction with unit combination instruments, DCS, PLC and other systems to provide on-site instrument signal isolation, signal conversion, signal distribution, signal processing and other functions, thereby improving the anti-interference ability of the industrial production process automatic control system and ensuring the stability and reliability of the system. This product is divided into three types: one in one out, one in two out, and two in two out, with input and output magnetic isolation. (Note: This product is prohibited from use in explosion-proof situations)

Parameters

Input signal4mA~20mA ,0mA~20mA ,0V~5V ,1V~5V ,0V~10V
Input impedanceCurrent impedance ≤ 50 Ω, voltage impedance ≥ 250K Ω
Maximum input current/voltage≤30mA/≤10.5V
Current isolator output 
output signal4mA~20mA 、0mA~20mA 、0V~5V 、1V~5V 、0V~10V
Output load4mA~20mA, 0mA~20mA load resistance RL ≤ 400 Ω;

0V~5V, 1V~5V load resistance RL ≥ 250K Ω, 0V~10V load resistance RL ≥ 500K Ω

Voltage isolator output 
output signal4mA~20mA 、0mA~20mA 、0V~5V 、1V~5V 、0V~10V
Output load4mA~20mA, 0mA~20mA load resistance RL ≤ 400 Ω;

0V~5V, 1V~5V, 0V~10V load resistance RL ≥ 20K Ω

source 
sourceDC20~32V
power dissipationSingle output power consumption: ≤ 0.8W; Dual output power consumption: ≤ 1.0W
Other parameters 
insulation resistance

 

(between input/output/power supply)

≥ 100M Ω (at 500VDC)
Insulation strength

 

(between input/output/power supply)

2000Vrms (1 minute, no spark)
working temperature-10 ℃~50 ℃ (without condensation or freezing)
relative humidity25% RH~85% RH
Storage temperature-10 ℃~60 ℃ (without condensation or freezing)
temperature drift0.0075% FS/℃
Installation methodInstallation of 35mm DIN rail
Installation dimensions13mm * 108mm * 121.2mm (width * height * depth)
Transmission accuracy (20 ℃)0. 1%FS
response timeCurrent signal input ≤ 2ms; Voltage signal input ≤ 10ms
weightAbout 130 grams
Electromagnetic compatibilityComply with GB/T18268 Industrial Equipment Application Requirements (IEC 61326-1)
Applicable on-site equipmentDC voltage/current source

Documents

Take the next step

Get a Quote

Request a quote from us based on your specific requirements

To be a Distributor

If you want to distribute sentec brand in your local area, you can contact us for more.

Installation & Maintain

A group of  professional engineer is here to help your sensor installation & maintenance.