SEM228T-B Class B Thermoelectric Pyrgeometers

The SEM228T-B Class B Thermoelectric Pyrgeometers is a shortwave total radiation sensor used for solar radiation observation. It is a Class-I total radiation sensor conforming to the latest ISO 9060 and WMO technical standards.

The SEM228T-B Class B Thermoelectric Pyrgeometers is a shortwave total radiation sensor used for solar radiation observation. It is a Class-I total radiation sensor conforming to the latest ISO 9060 and WMO technical standards.

The SEM228T-B total radiation sensor measures solar radiation received by a horizontal plane from a solid angle of 2π steradian degrees (hemispherical direction), measured in W/m². The SEM228T-B operates in a completely passive mode, utilizing a thermopile sensor to generate an output voltage proportional to the incident radiation flux. The use of two spherical glass domes reduces measurement errors, particularly thermal offset, resulting in high measurement accuracy.

Application

Used for meteorological observation, building physics, climate, and solar energy harvesting experiments. A common application is as part of a weather station to measure outdoor solar radiation.

Parameters

Classified according to ISO 9060/WMO standardsGrade B/Good Quality
Response time (95% response)<10s
Zero-point offset:(a) Corresponding to 200 W/m² net thermal radiation (ventilation)<15 W/m²
Zero-point offset:(b) Response to Ambient Temperature Variation of 5 K/h<4W/m²
Stability (Variation/Year, Percentage of Full Scale)±1.5%
Nonlinearity±1%(100~1000 W/m²)
Directional Response±20 W/m²
Temperature Response<4%(-10~40℃)
Tilt Response<2%
Sensitivity Range7-14μV/(W/m²)
Operating Temperature-40~+80℃
Internal Resistance<50Ω
Standard Cable Length3m
Measurement Range0~2000W/m²
Cable ReplacementUsers can remove and install cables
Spectral Range280~3000 nm (50% transmittance)
Reading RequirementsOne differential voltage channel or one single-ended voltage channel
Horizontal CalibrationIncludes bubble level and adjusting feet
Solar Exposure Uncertainty±2%
Weight (excluding cable)0.8kg
Calibration TraceabilityWRR traceability, procedure according to ISO9847
Recommended Calibration CycleBiennially
Output SignalOriginal output 0~20mV,Optional RS485/4~20mA output (not for external transmitter)