FHS300 Wall Fixed High Accuracy Ultrasonic Flowmeter/Heat Meter

FHS300 is based on the original imported FPGA integrated circuit from America’s Intel corporation. Its algorithm belongs to combination of threshold comparison gate circuit delay method and high-speed ADC correlation method. The main advantage is reflected in clamp-on ultrasonic flow meter. It is different from other 99% domestic clamp-on ultrasonic flow meters which are using the outdated capacitor charging algorithm or using algorithm of either comparison or correlation alone.

FHS300 is based on the original imported FPGA integrated circuit from America’s Intel corporation. Its algorithm belongs to combination of threshold comparison gate circuit delay method and high-speed ADC correlation method. The main advantage is reflected in clamp-on ultrasonic flow meter. It is different from other 99% domestic clamp-on ultrasonic flow meters which are using the outdated capacitor charging algorithm or using algorithm of either comparison or correlation alone. So, our FHS300 belongs to high-end transit-time ultrasonic flow meter. Its measuring frequency can be more than 300 times per second (domestic other 99% clamp-on ultrasonic flow meters are less than 50 times per second, or even just once per second). Its accuracy is strictly controlled to be better than 1.0%. Moreover, its tolerance rate to bubbles in the measured pipe has been greatly improved, and the maximum tolerance time for continuous bubbles or impurities is 5 seconds.

Parameters

Flow range±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy±1% of measured value
Repeatability0.2% of measured value
Linearity±1%
Pipe sizeDN25mm~DN1200mm(A pair of sensors)
 

Outputs

Analog output: 4~20mA, max load 750Ω .

Pulse output: 0~10KHz

CommunicationRS232/RS485 Modbus
Power supply10~36VDC/AC90~245V
Display240*128 backlit LCD
 

 

 

Temperature

Transmitter: -14℉~140℉(-20℃~60℃)

Transducer: -40℉~176℉(-40℃~80℃,TT01)

Transducer: -40℉~266℉(-40℃~130℃,TT03)

Transducer: -40℉~356℉(-40℃~180℃,TT02H)

HumidityUp to 99% RH,non-condensing
TransmitterPC+ABS,IP65
 

Transducer

Encapsulated design,IP68

Double-shielded transducer cable

Standard/maximum cable length:30ft/1000ft(9m/300m)